Skip to main content

Voltage Stabilisers / Conditioners mSVR Series

  • Servo Electronic
  • Single Phase
  • 1 to 15 kVA
Sinalda UK mSVR Series

mSVR Series - Single-Phase Voltage Stabilisers / Power Line Conditioners

The Mini SVR Series of Single-Phase AC Automatic Voltage Stabiliser / Conditioners are designed to provide a clean and regulated power supply, thereby ensuring reliable protection against the vagaries of the utility mains supply.

Models are available in 7 different power ratings:

1 kVA (1kW), 2 kVA (2kW), 3 kVA (3kW), 5 kVA (5kW), 7.5 kVA (7.5kW), 10 kVA (10kW) and 15kVA (15kW).

By steplessly boosting low voltages and reducing down high voltages, they ensure a stable output voltage. In addition, Mini SVR Series Voltage Stabilisers safeguard against all too common everyday transient voltages and spikes – typically introduced into the mains supply by nearby disturbances resulting from peak power demands or stop/start operation of electrical machinery.

Suitable for all electronic and electrical load types models are available for situations where the incoming mains utility supply is between 165V to 265V (H Models) and, 90V to 140V (L Models).

mSVR Single Phase Voltage Stabilisers / Conditioners
mSVR Single Phase Voltage Stabilisers / Conditioners

mSVR Single Phase Voltage Stabilisers / Conditioners

1 / 20

To learn more about the range of Single-Phase mSVR Voltage Stabilisers available from Sinalda UK, please check out the following listings, or download the brochure below:

UPDATE: Now with extended range coverage to 15 kVA

Standard Features

include:

  • Cost-Efficient Microprocessor Controlled Step-Less Voltage Stabilization / Regulation
  • Servo Electronic Digitally Enhanced Design
  • Brownout and Over / Under Voltage Protection
  • Wide Permissible Input Voltage Window
  • TVSS – Transient Voltage Surge & Spike Suppression Protection
  • Basic Electrical Noise Protection
  • Class II SPD – Lightning Surge Arrestor
  • Restart Time Delay to Limit Nuisance Tripping & Protect Sensitive Load Equipment from Damage
  • Servo Electronic Digitally Enhanced Design with User Selectable Response Times, Restart Time Delay, Output Voltage & Accuracy
  • Comprehensive Front Display Panel Display with – Input & Output Voltage Digital Metering – Output Current Digital Metering – Full LED Status Indication
  • User Selectable Operating Parameters (via the Display Panel) – Output Voltage & Accuracy – Over & Under Voltage Levels – Overload – Speed of Correction – Restart Time Delay
  • Input Circuit Breaker / Switch
  • Manual Bypass Switch (with interlocking)
  • Hard Wire Input & Output (IEC 320 Plug N Play ≤2 kVA)
  • RS/232 Interface
  • Built to comply with leading International Standards
  • Supplied with a 2 Year / 24 Months Warranty

Optional Features

available include:

  • 19” Rack Mountable Enclosure (-RM)
  • IP54 / NEMA 3 Style Outdoor Enclosure (-IP54)

Sinalda UK mSVR Series

Selection Table:

Model No:mSVR-1HmSVR-2HmSVR-3HmSVR-5HmSVR-7.5HmSVR-10HmSVR-15H
Max. Rating:kVA/kW12357.51015
Amps4.38.613.021.732.643.565.2
Input Voltage Window:165 to 265V Single Phase, 2 Wire (L, N +G/E)
Output Voltage:Default 230V (adjustable 220~240V) Single Phase, 2 Wire (L, N & G/E)
Output Voltage Accuracy:Default ±1 to 2% (Adjustable ±1% to ±4%)
Max Input:Amps7131932486589
Input & Output Connections:IEC 320 C13 with 2 x IEC Power CablesHardwire – Screw Terminals
Physical Size:W x H x D mm210 x 210 x 292243 x 280 x 342303 x 320 x 402400 x 590 x 400430 x 700 x 450
Mounting:On Rubber FeetOn Castors
Weight:Kg12131627317694
Packed Size:W x H x D cm30 x 30 x 3732 x 40 x 4139 x 41 x 4748 x 76 x 4853 x 96 x 53
Packed Weight:Kg13.51420293389109
Individual Model Info Sheets:PDFPDFPDFPDFPDFPDFPDF

Sinalda UK mSVR Series

Note: All mSVR Stabilisers/Conditioners are designed to support the full load at minimum input volts and maximum ambient temperature.

Sinalda UK mSVR Series

Selection Table:

Model No:mSVR-1 LmSVR-3LmSVR-5L
Max. Rating:kVA/kW135
Amps8.325.041.6
Input Voltage Window:90 to 140V Single Phase, 2 Wire (L, N +G/E)
Output Voltage:Default 120V (adjustable 110~127V) Single Phase, 2 Wire (L, N & G/E)
Output Voltage Accuracy:Default ±1 to 2% (Adjustable ±1% to ±5%)
Max Input:Amps113762
Input & Output Connections:IEC 320 C13 with 2 x IEC Power CablesHardwire – Screw Terminals
Physical Size:W x H x D mm243 x 280 x 342303 x 320 x 402400 x 590 x 400
Mounting:On Rubber FeetOn Castors
Weight:Kg112656
Packed Sizes:W x H x D cm30 x 30 x 3739 x 41 x 4748 x 76 x 48
Packed Weight:Kg142867
Individual Model Info Sheets:PDFPDFPDF

Sinalda UK mSVR Series

Note: All mSVR Stabiliser/Conditioners are designed to support the full load at minimum input volts and maximum ambient temperature.

Sinalda UK mSVR Series

LED STATUS INDICATORS & ALARMS
Sinalda UK mSVR SeriesNormalAll is working fine
Sinalda UK mSVR SeriesTime DelayDelay in the supply of power to the output on start-up and re-engagement of the output after an irregular event Display Metering will show a count-down to the re-engagement of the output
Sinalda UK mSVR SeriesHigh VoltageOutput voltage exceeds the selected over-voltage level. The output will be automatically disconnected. On fault clearance, the output will be automatically re-engaged
Sinalda UK mSVR SeriesLow VoltageOutput voltage exceeds the selected under-voltage level. The output will be automatically disconnected. On fault clearance, the output will be automatically re-engaged
Sinalda UK mSVR SeriesOverloadThe actual current drawn on the input supply exceeds the models stated maximum input current rating. LED will indicate an overload condition for 60 seconds and then the output will be automatically disconnected. On fault clearance, the system will require a manual restart
Sinalda UK mSVR SeriesMenuPassword-protected access for setting the Stabiliser/Conditioner’s 7 user-definable system parameters (with menu navigation buttons). User-adjustable parameters are- 1. Output Voltage 2. Output Voltage Accuracy 3. Output Under-Voltage Level 4. Output Over-Voltage Level 5. Input Overload level 6. Speed of Response 7. Time Delay
DIGITAL METERING
Sinalda UK mSVR SeriesInput Volt MeterThe voltage level of the incoming utility mains supply
Sinalda UK mSVR SeriesOutput Volt MeterThe Output voltage delivered by the system
Sinalda UK mSVR SeriesLoad AmmeterThe power drawn by the connected load and stabiliser

General Technical Specification

General:
Design Topology:Servo Electronic – Variable Transformer controlled
Phase:Single Phase, 2 Wire (L+N+GE)
Model Nos:H SeriesmSVR-1H to mSVR-15H ( 1 to 15 kVA)
L SeriesmSVR-1L to mSVR-5L (1 to 5 kVA)
Power Ratings:7 Model Ratings- 1 kVA, 2 kVA, 3kVA, 5kVA, 7.5kVA, 10kVA , & 15kVA
Frequency:50 / 60Hz (35 to 63Hz)
Power Factor:The Power Factor has no effect on performance providing the stabilizer is being used within its rated capacity
Input:
Nominal Voltage:H Series 220V – 230V – 240V, Single Phase, 2 Wire (L+N+GE)
L Series110V – 120V – 127V, Single Phase, 2 Wire (L+N+GE)
Input Voltage WindowH Series165V to 265V, Single Phase, 2 Wire (L+N+GE)
L Series90V to 140V, Single Phase, 2 Wire (L+N+GE)
Output:
Voltage:H Series 220V – 230V – 240V (Selectable), Single Phase, 2 Wire (L+N+GE)
L Series110V – 120V – 127V (Selectable), Single Phase, 2 Wire (L+N+GE)
Voltage Accuracy:±1 to 2% (Default) – adjustable ±1% to ±5%
Response Time:Typically a 10% supply variation will be corrected to within 2.5% in 0.6 seconds
Efficiency:≥98%
Metering, Alerts & Communication:
Metering:Input Volts, Output Volts, and Load
Alarms / Indicators:Restart Delay, Normal, Irregular, Low Volt, High Volt & Overload
User Selectable Operating Parameters (via the Display Panel)Output VoltageH Series – 230V (Default) – adjustable 220V to 240V L Series – 120V (Default) – adjustable 110V to 127V
Output Voltage Accuracy±1 to 2% (Default) – adjustable ±1% to ±5%
OverloadOn the Input
Speed of Correction4 selectable speeds
Over Voltage LevelOn the Output
Under Voltage LevelOn the Output
Restart Time Delay5 seconds (Default) – adjustable 1 to 999 seconds
InterfaceRS-232 – DB9 Pin Style Port
Protection Features:
Input Breaker & Manual Bypass:Standard on all models (with interlocking)
Over/ Under VoltageDisplay Indication with the automatic disconnection of the output
Short-Circuit:Automatic tripping of the input circuit breaker/switch
Loss of SupplyAuto-restart on the return of the utility mains supply
Restart Time Delay:Default 5 seconds (adjustable 1 to 999 seconds) – to prevent nuisance tripping and protect sensitive equipment against damage. Count down displayed on the Display Front Panel.
Surge Protection:TVSS – Protects loads against high-energy Spikes and Transient Voltages
Lightning Surge Protection:Class II SPD
Noise Filtering:LC Filter delivering Common Mode and Differential Mode Attenuation of 50dB at 100kHz
Overload Protection:Display Indication with the automatic disconnection of the output
Overload Ratings:Operational Overload Settings are set via the Digital Display Panel, with electro-mechanical overload ratings standing at 10 x Max. Current for 100 milliseconds 2.5 x Max. Current for 10 seconds 1.5 x Max. Current for 1 minute
Environmental:
Operating Temperature Range:-0°C to +45°C Derate by 2% for each additional °C up to max 60°C
Maximum Altitude:1000 meters (derate by 2.5% per additional 500 meters)
Relative Humidity:Suitable for indoor tropical use – 0 to 95% (non-condensing)
Physical:
Power Connections:1 & 2 kVA modelsIEC320 Input & Output Connectors
All other modelsHardwire Input & Output (with rear and bottom cable entry)
Construction:IP20 / NEMA 1 Style – BS EN 60529
Paint Colour:RAL 1013 (Oyster White – Epoxy Powder Coating)
Dimensions & Weights:See relevant model Selection Tables (above)
Certification & Conformance:
EMC Conformance:BS EN 55022 and relevant parts of BS EN 61000
CE Certification:CE Marked – 2014/30/EU (The EMC Directive) and 2014/35/EU (The Low Voltage Directive)
Warranty:2 Years / 24 Months from date of supply
Optional Add-Ons:
Rack-Mountable (-RM)19” Rack Mountable Enclosure (mSVR-1H to 7.5H and 1L to 3L Models only)
Outdoor IP54 Enclosure (-IP54)Outdoor IP54 / NEMA 3 style free-standing steel cubicles suitable for external use, or more challenging internal environments

Note: All mSVR Stabilisers/Conditioners are designed to support the full load at minimum input volts and maximum ambient temperature.

Sales & Support

CE & UKCA Certification 

mSVR Series Single-Phase Servo Electronic AC Voltage Stabilisers / Power Line Conditioners comply with the relevant European Union – and corresponding UK – health, safety, and environmental protection directives and regulations and are duly CE / UKCA marked.

Sinalda UK Declaration

  • EMC Directive – 2014/30/EU – in force from April 2016
    Low Voltage Directive – 2014/35/EU – in force from April 2016 and corresponding UK regulations

Independent 3rd Party Verification Certificate

  • EMC Directive – 2014/30/EU – in force from April 2016
    Low Voltage Directive – 2014/35/EU – in force from April 2016

You can either buy direct from us, or via one of our approved resale partners or, if you prefer, online at –

AMAZON UK

Buy on Amazon UK

[Click on the Rating]

H Series  (220-240V)
>> 1kVA>> 2KVA>> 3kVA>> 5kVA>> 7.5 kVA>> 10kVA>> 15kVA
L Series (110-127V)
>> 1kVA >> 3kVA>> 5kVA

If you do not find the Voltage Stabiliser or Power Line Conditioner that meets your application’s exact needs, please contact us with your specific detailed requirements.

Request a quote
trustedsite