AC Voltage Stabilisers / Power Conditioners ESR Series
- Single-Phase Static Electronic
- 3 to 100 kVA

ESR Series - Single Phase Static Electronic AC Voltage Stabilizers - 3 to 100kVA
Ideal for general commercial and industrial applications, ESR Static Electronic Single-Phase Voltage Stabilisers not only guard against voltage fluctuations they also offer protection against all too common harmful high-energy surges, transients and voltage spikes.
Offered as two ranges, in ratings from 3 to 100 kVA, H Series models support international 220 to 240 Volt utility mains supplies and L Series models support US-Style utility supplies of 110 to 127 volts.
As a virtually maintenance-free solution, models are also available in IP54 / NEMA 3 Style Enclosures (-IP54 Option) and as Power Line Conditioners (-PC Option).
To learn more about the ESR ranges of Single-Phase Static Voltage Stabilisers available from Sinalda UK, please check out the listings, or download the brochure below:
Standard Features include:
- Automatic Digital Microprocessor Controlled Voltage Stabilization / Regulation
- Static Electronic Design – Virtually Maintenance Free
- Wide Permissible Input Voltage Window (up to ±50%)
- TVSS – Transient Voltage Surge & Spike Suppression Protection
- Over and Under Voltage Protection
- Comprehensive Digital Front Panel with
– Input & Output Voltage Metering
– Output Current Metering
– Full Status Indication - Start-Up Load Protection
- Class II Lightning Surge Arrestors
- Automatic Electronic Bypass
- Freestanding IP20 Indoor Enclosure
- Hard Wire Input & Output
- Built to comply with leading International Standards
- Supplied with a 2 Year / 24 Months Warranty
Optional Features available include:
- Outdoor IP54 Enclosure (-IP54)
Stabiliser presented in endurable IP54 (BS / EN 60529) / NEMA 3 free-standing steel cubicles suitable for external use, or more challenging internal environments - Input Isolating Transformer (-PC)
The integration of a shielded isolation transformer provides enhanced spike & electrical noise (Common Mode: 120db @ 100khz & Normal Mode Noise: 60db @ 100khz) suppression and neutral ground bonding. Delivers what is commonly referred to as a ‘CLEAN’ supply - AquaStop (-AS)
PCB protective coating offers protection against dampness and moisture ingress - Additional Digital Metering (-ADM)
Additional Digital Metering for Frequency & Power Factor - Inbuilt Surge Rating (-SR50)
150% Surge Rating for 10 seconds – Recommended for inductive load types - Alternative Paint Colour (-RAL)
Alternative Paint Colour Finish – customer to specify
SELECT | Permissible Input Voltage Window Options (–S*):
| Swing Options | Nominal Voltage | Max Model Rating | |||
|---|---|---|---|---|---|
| 220V | 230V | 415/240V | |||
| S15 | ±15% | 187 to 253V | 196 to 265V | 204 to 276V | 100 kVA |
| S20 | ±20% | 176 to 264V | 184 to 276V | 192 to 288V | 100 kVA |
| S25 | ±25% | 165 to 275V | 173 to 288V | 180 to 300V | 100 kVA |
| S30 | ±30% | 154 to 286V | 161 to 299V | 168 to 312V | 100 kVA |
| S35 | ±35% | 143 to 297V | 150 to 311V | 156 to 329V | 100 kVA |
| S40 | ±40% | 132 to 308V | 136 to 322V | 144 to 336V | 100 kVA |
| S45 | ±45% | 121 to 319V | 127 to 334V | 132 to 348V | 75 kVA |
| S50 | ±50% | 110 to 330V | 115 to 345V | 120 to 360V | 75 kVA |
SELECT | Required Power Rating:
| Power Rating (kVA) | Max Rating (Amps per Phase) | ESR-H Model No (S*=Add Swing Option No) | |||
|---|---|---|---|---|---|
| kW | 220V | 230V | 240V | ||
| 3 kVA | 2.4 | 11A | 11A | 10A | ESR-3H-S* |
| 5 kVA | 4 | 19A | 18A | 17A | ESR-5H-S* |
| 8 kVA | 6.4 | 30A | 28A | 27A | ESR-8H-S* |
| 10 kVA | 8 | 37A | 35A | 34A | ESR-10H-S* |
| 15 kVA | 12 | 55A | 53A | 50A | ESR-15H-S* |
| 20 kVA | 16 | 73A | 70A | 67A | ESR-20H-S* |
| 30 kVA | 24 | 110A | 105A | 100A | ESR-30H-S* |
| 40 kVA | 32 | 146A | 140A | 134A | ESR-40H-S* |
| 50 kVA | 40 | 182A | 174A | 167A | ESR-50H-S* |
| 60 kVA | 48 | 219A | 209A | 200A | ESR-60H-S* |
| 75 kVA | 60 | 273A | 261A | 250A | ESR-75H-S* |
| 100 kVA | 80 | 364A | 348A | 334A | ESR-100H-S* |
Note: All ESR-T1F Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
Also available as a Voltage Step-Down Solution (HL Models)
Ideal for applications where the utility supply voltage is different from the load equipment’s requirements (eg Utility Mains Input 230V / Load Requirement 120V)

SELECT | Permissible Input Voltage Window Options (–S*):
| Swing Options | Nominal Voltage | Max Model Rating | ||||
|---|---|---|---|---|---|---|
| 110V | 115V | 120V | 127V | |||
| S15 | ±15% | 94 to 127V | 98 to 132V | 102 to 138V | 106 to 146V | 60 kVA |
| S20 | ±20% | 88 to 132V | 92 to 138V | 96 to 144V | 102 to 152V | 60 kVA |
| S25 | ±25% | 83 to 138V | 86 to 144V | 90 to 150V | 95 to 159V | 40 kVA |
| S30 | ±30% | 77 to 143V | 81 to 150V | 84 to 156V | 89 to 165V | 40 kVA |
SELECT | Required Power Rating:
| Power Rating (kVA) | Max Rating (Amps per Phase) | ESR-L Model No (S*=Add Swing Option No) | ||||
|---|---|---|---|---|---|---|
| kW | 110V | 115V | 120V | 127V | ||
| 3 Kva | 2.4 | 21A | 20A | 20A | 18A | ESR-3L-S* |
| 5 kVA | 4 | 36A | 34A | 33A | 31A | ESR-5L-S* |
| 8 kVA | 6.4 | 58A | 55A | 53A | 50A | ESR-8L-S* |
| 10 kVA | 8 | 72A | 69A | 66A | 62A | ESR-10L-S* |
| 15 kVA | 12 | 109A | 104A | 100A | 94A | ESR-15L-S* |
| 20 kVA | 16 | 145A | 139A | 133A | 125A | ESR-20LP-S* |
| 30 kVA | 24 | 218A | 208A | 200A | 188A | ESR-30L-S* |
| 40 kVA | 32 | 290A | 278A | 266A | 251A | ESR-40L-S* |
| 50 kVA | 40 | 363A | 347A | 333A | 314A | ESR-50L-S* |
| 60 kVA | 48 | 436A | 417A | 400A | 377A | ESR-60L-S* |
| 80 kVA | 60 | 545A | 521A | 500A | 472A | ESR-80L-S* |
| 100 kVA | 80 | 727A | 695A | 666A | 629A | ESR-100L-S* |
Note:
All ESR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature
Also available as a Voltage Step-Up Solution (LH Models)
Ideal for applications where the utility supply voltage is different from the load equipment’s requirements (eg Utility Mains Input 120V / Load Requirement 230V)
General Technical Specification
| General: | ||
| Design Topology: | Digital Buck-Boost SCR Design Topology | |
| Phase: | H & L Series | Single Phase, 2 Wire (1P+N+G/E) |
| Power Ratings: | 12 Model Ratings- 3kVA, 5kVA, 8kVA, 10kVA, 15kVA, 20kVA, 30kVA, 40kVA, 50kVA, 60kVA, 75kVA & 100kVA | |
| Frequency: | 50 / 60Hz (47 to 63Hz) | |
| Power Factor: | 0.8 pf | |
| Input: | ||
| Nominal Voltage: | H Series | 220V -230V – 240V, Single Phase, 2 Wire |
| L Series | 110V – 115V – 120V – 127V, Single Phase, 2 Wire | |
| Input Voltage Window Options (S*): | S15 | Nominal Voltage ±15% (All Series) |
| S20 | Nominal Voltage ±20% (All Series) | |
| S25 | Nominal Voltage ±25% (All Series) | |
| S30 | Nominal Voltage ±30% (All Series) | |
| S35 | Nominal Voltage ±35% (H Series Only) | |
| S40 | Nominal Voltage ±40% (H Series Only) | |
| S45 | Nominal Voltage ±45% (H Series Only) | |
| S50 | Nominal Voltage ±50% (H Series Only) | |
| Output: | ||
| Voltage: | H Series | 220V -230V – 240V, Single Phase, 2 Wire |
| L Series | 110V – 115V – 120V – 127V, Single Phase, 2 Wire | |
| Voltage Accuracy: | S15 to S20 Option Models | ±3% (Default) – adjustable ±1% to ±5% |
| S25 to S40 Option Models | ±3% (Default) – adjustable ±3% to ±5% | |
| S45 to S50 Option Models | ±5% | |
| Correction Time: | Within 60 milliseconds (3 to 4 Cycles) per Step | |
| Efficiency: | ≥95% | |
| Maximum Output Current Rating: | Up to 100% (set via Digital Display Panel) | |
| Display Panel – Metering, Alerts & Communication: | ||
| Front Display Panel: | Digital Metering: | Input Volts, Output Volts, and Load |
| Status Indication: | Overload, Over-Volts, Under-Volts & SCR Fuse Blown | |
| Display Settable Parameters: | Output Voltage, Output Voltage Accuracy, Correction Time, Over-Voltage Level, Under-Voltage Level & Over Current Limit | |
| Interface: | RS-485 – DB9 Pin Style Port | |
| Protection Features: | ||
| Surge Protection: | TVSS – Protects loads against high-energy Spikes and Transient Voltages | |
| Lightning Surge Protection: | Class II SPD – protection against extremely high voltage surges and transients caused by lightning strikes on the utility mains supply line | |
| Input Breaker: | Standard on all models – delivers over current input protection | |
| Manual Bypass: | ‘Break Before Make’ bypass facility (with mechanical interlocking) offers the ability to route the supply feed to bypass the stabiliser/conditioner. Useful when performing deep maintenance on the system or in the improbable event of a system malfunction. | |
| Output Isolation: | Automatic disconnection of the load in the event of a fault condition is detected | |
| Automatic Bypass: | Automatic transfer to Bypass in the event of an overload or unlikely system fault | |
| Environmental: | ||
| Operating Temperature Range: | 0°C to +45°C Derate by 2% for each additional °C up to max 60°C | |
| Maximum Altitude: | 1000 meters (derate by 2.5% per additional 500 meters) | |
| Relative Humidity: | Suitable for indoor tropical use – 0 to 95% (non-condensing) | |
| Harmonic Distortion: | None introduced | |
| Audible Noise: | 45 to 65 dB – dependent on model selected and ambient background noise level. | |
| Physical: | ||
| Power Connections: | Hardwire Input & Output | |
| Construction: | Enclosures to IP20 / NEMA 1 Style – BS EN 60529 (Option – Outdoor IP54/NEMA 3 Style) | |
| Paint Colour: | RAL 7032 (Pebble Grey – Epoxy Powder Coating) – Other paint colours on specific request | |
| Dimensions & Weights: | Dependent on model rating and configuration Sizes and weights available on individual request | |
| Certification & Conformance: | ||
| EMC Conformance: | BS EN 55022 and relevant parts of BS EN 61000 | |
| CE Certification: | CE Marked – 2014/30/EU (The EMC Directive) and 2014/35/EU (The Low Voltage Directive) | |
| Warranty: | 2 Years / 24 Months from the date of supply | |
| Optional Add-Ons: | ||
| Outdoor IP54 Enclosure (-IP54) | Stabiliser presented in endurable IP54 (BS / EN 60529) / NEMA 3 free-standing steel cubicles suitable for external use, or more challenging internal environments | |
| Inbuilt Surge Rating: | (-SR50) 150% Surge Rating for 10 seconds – Recommended for inductive load types | |
| Input Isolating Transformer (-PC) | The integration of a shielded isolation transformer provides enhanced spike & electrical noise (Common Mode: 120db @ 100khz & Normal Mode Noise: 60db @ 100khz) suppression and neutral ground bonding. Delivers what is commonly referred to as a ‘CLEAN’ supply | |
| AquaStop (-AS) | PCB protective coating offers protection against dampness and moisture ingress | |
| Additional Digital Metering (-ADM) | Additional Digital Metering for Frequency & Power Factor | |
| Load Surge Rating (-SR50) | 150% Surge Rating on the maximum load rating of the stabiliser for 10 seconds – recommended for inductive load types | |
| Alternative Paint Colour (-RAL) | Alternative Paint Colour Finish – customer to specify | |
Inductive Loads: Where the load type is inductive in nature, such as motors (fans, pumps, etc.), solenoids, and relays, high inrush current and short-time overload factors must be fully considered. With motors (without a soft start facility) typically drawing on start-up current 5 to 7 times the stated rating of the motor, it is recommended that a Static Voltage Stabiliser is selected that is three times the stated rated capacity of the load and that the inrush current does not exceed the listed “Maximum Output Current Rating” of the stabiliser or stabiliser with the SR50 option – if fitted.
Note:
All ESR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
Sales & Support
- Data Sheet – H Series
[220V to 240V Models] - PDFData Sheet – L Series
[110V to 127V Models] - DOC
Guide Specification
Operator / User Manual
Please contact us to request a copy of the Manual
CE and UKCA Certification
ESR Series Single-Phase Static-Electronic AC Voltage Stabilisers / Power Line Conditioners comply with the relevant European Union – and corresponding UK – health, safety, and environmental protection directives and regulations and are duly CE / UKCA marked.
Sinalda UK Declaration
- PDF
EMC Directive – 2014/30/EU – in force from April 2016
Low Voltage Directive – 2014/35/EU – in force from April 2016
If you do not find the Static Voltage Stabilizer that meets your application’s exact needs, please contact us with your specific detailed requirements.